Loading...

Electrolytic starter Vectrohm R120

Electrolytic starter Vectrohm R120, specially designed for starting wound rotor motors – ring motors – or cage motors:

For wound rotor motors (called ring motor), the maximum power accepted by the Vectrohm R120 is :

  • 160 kW for start on load
    200 kW for no-load start
    For cage motors, the maximum motor power accepted by the Vectrohm R120 is:
  • 110 kW for start on load
    132 kW for no-load start
    Switch rating: 140T
    Applications: Fans, Refiners, Pumps, Ball mills, hammer mills, roundabouts….

Rotor voltage up to 600V
Run command: 230V power supply controlled by the stator line contactor
Start-up time: From 5 to 35 seconds

Technical specifications

  • H (mm) 900 x l (mm) 560 x L (mm) 735
  • Capacity 120 Liters
  • Empty weight 65 kg
  • Full weight 185 kg
  • A (mm) 275 and B (mm) 525
schematic vectrohm R25
Ask for a quote
Vectrohm-logo-separateur

The so-called rotor starter is suitable for all types of motors such as ball mills, jaw mills, impact mills, compressors, belt conveyors, crushers, mixers, saws, pumps, fans, ski-lifts or all asynchronous ring motors.

kit maintenance vectrohm demarrreur electrolytique

Ask a request

Our experts will contact you within 24 hours. You can contact them directly on 01 60 62 08 00 to get an answer to your questions within minutes.

démarreur électrolytique R25 - R65